Solar Panel Calculator

Energy

From a power bill to a panel count.

Interactive Tool
Live Calculation

Solar Panel Calculator

Array kW = annual kWh / (365 x peak sun hours x (1 - losses)); panels = ceiling(array W / panel W).

kWh
kWh
h
h
W
W
%
%
sq ft
sq ft
Evaluated Formula:Array kW = annual kWh / (365 x peak sun hours x (1 - losses)); panels = ceiling(array W / panel W).
Guidance:
Peak sun hours are not daylight hours. They are the equivalent hours of full-strength sun, typically 3-6 in the US depending on location and season.
System losses of 10-20 percent cover inverter conversion, wiring, soiling, heat, and mismatch. Keep the figure honest rather than optimistic.
Panel count is rounded up, so the installed array usually generates slightly more than the target. Use the installed size for cost and interconnection planning.
Array size needed
7.16 kW

Calculated instantly

Panels needed18
Estimated annual generation10,052.1 kWh
Roof area needed324 sq ft
Array size installed7.2 kW

Embed this calculator

Put this calculator on your own site with the snippet below. The frame contains the tool only, reports its own height, and carries a visible link back to the full page. Embedding is free; keep the attribution link as it is, and do not wrap the frame in a way that hides it.

Preparing the embed code for this page...

What This Calculator Does

The Solar Panel Calculator sizes an array from annual electricity use, peak sun hours, panel wattage, and system losses. It returns the array size needed, the number of panels after rounding, the roof area, and the generation the rounded array should produce.

How It Works

Annual kWh is divided by 365 to get daily use, then by peak sun hours and by the efficiency remaining after losses. That gives the direct current array size in kilowatts. Multiplying by 1,000 and dividing by panel wattage gives a fractional panel count, which is rounded up. The installed array size and estimated generation are recalculated from the whole panel count so the numbers agree.

Example

A home using 10,000 kWh a year in a 4.5 peak sun hour location with 15 percent losses needs 10,000 / (365 x 4.5 x 0.85) = 7.16 kW. At 400 W per panel that is 18 panels, an installed array of 7.2 kW, roughly 10,052 kWh a year, and about 324 sq ft of roof area.

Formula

Array size
annual kWh / (365 x peak sun hours x (1 - losses))
Panels
ceiling(array watts / panel watts)
Installed generation
panels x panel watts x sun hours x 365 x (1 - losses) / 1000
Roof area
panels x area per panel

Reading the Results

Array size needed

The direct current size before rounding to whole panels. It is a planning target, not a hardware configuration.

Panels needed

Whole panels at your wattage, rounded up. Panel dimensions and wattage vary, so confirm the actual product before committing to a layout.

Estimated annual generation

What the rounded array should produce under the assumed sun hours and losses. Real output varies by weather, shading, tilt, and inverter clipping.

Sources and References

  • National Renewable Energy Laboratory - PVWatts Calculator

    Hourly PV energy production model

    A location-specific simulation that accounts for weather, tilt, and orientation better than a hand calculation.

  • US Department of Energy - Solar Energy Technologies Office

    Solar system sizing and performance basics

    Background on capacity, capacity factor, and why real output differs from nameplate rating.

References identify the method or data behind this calculator. Where a standard or tariff changes, the current edition applies, and the assumptions stated above take precedence over a remembered figure.

Frequently Asked Questions

How many solar panels do I need for a normal house?

It depends on consumption, location, panel wattage, and roof orientation. A low-use home in a sunny climate may need 10-14 panels; a high-use home in a cloudy region may need 25 or more. Use your own annual kWh rather than a national average.

What are peak sun hours?

A measure of solar energy received per day expressed as hours of full-strength sun. Four peak sun hours means the day delivered the equivalent of four hours at 1,000 W per square metre. It is not the length of the day, and it changes with season.

What system losses should I assume?

Ten to twenty percent is a reasonable range for a residential system, covering inverter conversion, wiring, soiling, temperature, and module mismatch. Shade, snow, and an undersized inverter can push losses higher. A site-specific simulation is more accurate.

Does the calculator account for shading and roof orientation?

No. It assumes the array faces the sun well and is unshaded at the peak. A north-facing roof, a chimney shadow, or a steep pitch can cut output substantially. Use a shade study or PVWatts with your actual tilt and azimuth before sizing.

Should I size to 100 percent of my use?

That is a common starting point, but the best size depends on net metering, export rates, battery economics, and budget. In some tariffs, offsetting evening load with a battery is worth more than adding panels that export at a low rate. Model the tariff, not just the kWh.